| | Flow cytometer for analysis of cells, organisms or particles in suspension. Measure relative size and complexity, cell number, viability, apoptosis, DNA content, cell cycle, DNA/RNA ratios, cytokines, intracellular calcium, oxidative burst, intracellular pH, phagocytic activity and mitochondrial membrane potential. The HTS will run 96- and 384-well plates with a sample analysis time of approximately 15 minutes/96 well plate and a sample volume as low as 50ul. - 488nm and 633nm excitation lasers.
- 6 fluorescence parameters
- Acquisition rate up to 10000 events per second.
|
Room 1.42 M Block, 9346 4569 -
QEII
CMCA contact: flow.cmca@uwa.edu.au
| |
Flow cytometer for analysis of cells, organisms or particles in
suspension. Measure relative size and complexity, cell
number, viability, apoptosis, DNA content, cell cycle, DNA/RNA
ratios, cytokines, intracellular calcium, oxidative burst,
intracellular pH, phagocytic activity and mitochondrial
membrane potential.
- 488nm and 635nm excitation lasers.
- 4 fluorescence parameters.
- Acquisition rate up to 2000 events per second.
|
Room 1.42cl, M Block, 9346 4569 - QEII CMCA contact: flow.cmca@uwa.edu.au | |
Fluorescence activated cell sorter for collection of cells,
organisms or particles in suspension based on degrees of
expression of a trait.
- 488nm, 635nm, 350nm excitation lasers.
- 5 fluorescence parameters.
- Collection of 2 populations simultaneously.
- Sort speed up to 5000 events per second.
|
Room 1.40 M Block, 9346 2821 - QEII CMCA contact: flow.cmca@uwa.edu.au | |
The Luminex 200 instrument is a flexible bead array system for
multiplexing of up to 100 analytes per well. The
technology allows detection of soluble proteins from serum,
cell supernatant and tissue homogenates, as well as
oligonucleotides. Applications include the detection of
cytokines (replacing conventional ELISA), nucleic acid assays,
serology isotyping and enzyme-ligand research. Samples
are run in 96-well plates with sample volumes as low as 25
µl. The Luminex software is able to create standard
curves using a number of fitting methods and automatically
calculate analyte concentrations.
- A variety of multiplexing kits available for a large
range of analytes
- Application for both protein and nucleic acid assays
- Plate-based system able to run 96 samples and 100
analytes per hour.
|
| |
Flow cytometer for analysis of cells, organisms or particles in
suspension. Measure relative size and complexity, cell
number, viability, apoptosis, DNA content, cell cycle, DNA/RNA
ratios, cytokines, intracellular calcium, oxidative burst,
intracellular pH, phagocytic activity and mitochondrial
membrane potential.
- 488nm excitation laser.
- 3 fluorescence parameters.
- Acquisition rate up to 2000 events per second.
|
Room 556, MRF Building, 9224 0372 - RPH CMCA contact: flow.cmca@uwa.edu.au | |
BD FACSCalibur Flow Cytometer at BBCS |
Flow cytometer for analysis of cells, organisms or particles in
suspension. Measure relative size and complexity, cell
number, viability, apoptosis, DNA content, cell cycle, DNA/RNA
ratios, cytokines, intracellular calcium, oxidative burst,
intracellular pH, phagocytic activity and mitochondrial
membrane potential.
- 488nm and 635nm excitation lasers.
- 4 fluorescence parameters.
- Acquisition rate up to 2000 events per second.
|
Room 3.22B, MCS Building (BBCS), Crawley Campus. CMCA contact: flow.cmca@uwa.edu.au | Murdoch BD FACSCanto II | Flow cytometer for analysis of cells, organisms or particles in suspension. Measure relative size and complexity, cell number, viability, apoptosis, DNA content, cell cycle, DNA/RNA ratios, cytokines, intracellular calcium, oxidative burst, intracellular pH, phagocytic activity and mitochondrial membrane potential. The HTS will run 96- and 384-well plates with a sample analysis time of approximately 15 minutes/96 well plate and a sample volume as low as 50ul. - Violet 405nm, Blue 488nm and Red 633nm excitation lasers.
- 8 fluorescence parameters
- Acquisition rate up to 10,000 events per second.
- Instrument is located at Murdoch University.
| School of Animal Biology, Murdoch University. CMCA contact: flow.cmca@uwa.edu.au |
|